Welcome To Talentnetwork

Join Our Talent Network

What is a Talent Network

Joining our Talent Network will enhance your job search and application process. Whether you choose to apply or just leave your information, we look forward to staying connected with you.

Why Join?

  • Receive alerts with new job opportunities that match your interests
  • Receive relevant communications and updates from our organization
  • Share job opportunities with family and friends through Social Media or email

Join our Talent Network today!

Failure Analysis Engineer - Cu Chi (Having shuttle bus)

QM

Work Location Ho Chi Minh (Cu Chi District)
Job Level Experienced (Non - Manager)
Job Type Permanent
Qualification Bachelor
Experiences 3 - 4 Years
Salary Negotiable
Industry Quality Control (QA/QC), Manufacturing / Process, Electrical / Electronics / Electro Refrigeration
Deadline to Apply 14/06/2026
Contact Person thuong.vo@ttigroup.com.vn
Share Facebook Linkedin Save to my jobs

Job Benefit

  • Laptop
  • Insurance
  • Travel opportunities
  • Allowances
  • Employee Shuttle Service
  • Uniform
  • Incentive bonus
  • Health checkup
  • Training & Development
  • Salary review
  • Seniority Allowance
  • Annual Leave

Job Description

JOB SUMMARY:

As a Lithium-Ion Cell Failure Analysis Engineer, you will be responsible for identifying, analyzing, and resolving failure modes in battery cells. Your focus is to perform systematic failure investigations, determine root causes, and drive corrective and preventive actions across design and manufacturing processes.
You will work closely with cross-functional teams to improve product quality, reliability, and yield through deep technical analysis and data-driven insights

MAIN TASKS:

1. Failure Analysis Execution: Perform teardown and detailed failure analysis of lithium-ion cells (electrical, mechanical, thermal, and chemical failures). Identify failure modes such as internal short, lithium plating, contamination, weld defects, electrolyte issues, etc. Apply structured FA methodologies (8D, 5 Why, Fishbone, Fault Tree Analysis).
2. Root Cause Identification: Determine root causes using analytical techniques and data correlation (process, test, and field data). Differentiate between design-related, process-related, and usage-related failures. Build clear cause-effect relationships to support corrective actions.
3. Advanced Characterization & Diagnostics: Utilize FA tools and techniques such as: Microscopy (OM, SEM), Elemental analysis (EDS), X-ray / CT scanning, Electrochemical analysis (OCV, EIS, dQ/dV). Interpret results to identify failure mechanisms at material and cell level.
4. Corrective & Preventive Actions (CAPA): Work with process, design, and manufacturing teams to implement corrective actions. Validate effectiveness of actions through re-test or verification analysis. Support continuous improvement initiatives to reduce recurrence.
5. FA Database & Knowledge Management: Develop and maintain a structured FA database 1. Failure Analysis Execution: Perform teardown and detailed failure analysis of lithium-ion cells (electrical, mechanical, thermal, and chemical failures). Identify failure modes such as internal short, lithium plating, contamination, weld defects, electrolyte issues, etc. Apply structured FA methodologies (8D, 5 Why, Fishbone, Fault Tree Analysis).
2. Root Cause Identification: Determine root causes using analytical techniques and data correlation (process, test, and field data). Differentiate between design-related, process-related, and usage-related failures. Build clear cause-effect relationships to support corrective actions.
3. Advanced Characterization & Diagnostics: Utilize FA tools and techniques such as: Microscopy (OM, SEM), Elemental analysis (EDS), X-ray / CT scanning, Electrochemical analysis (OCV, EIS, dQ/dV). Interpret results to identify failure mechanisms at material and cell level.
4. Corrective & Preventive Actions (CAPA): Work with process, design, and manufacturing teams to implement corrective actions. Validate effectiveness of actions through re-test or verification analysis. Support continuous improvement initiatives to reduce recurrence.
5. FA Database & Knowledge Management: Develop and maintain a structured FA database for failure modes, root causes, and lessons learned. Standardize FA procedures and reporting templates for technician usage.
6. Reporting & Communication: Prepare clear and structured FA reports including Problem description, Failure mode, Root cause, Supporting evidence, Recommended actions. Present findings to internal stakeholders and management.
7. Cross-functional Collaboration: Collaborate with: R&D, Manufacturing, Quality. Provide technical guidance on failure risks and mitigation strategies

 

Job Requirement

Education: Bachelor’s or Master’s degree in: Electrochemistry, Materials Science, Chemical Engineering, Electrical/Electronic Engineering, or related fields

Experience:Min 2 years in manufacturing or battery-related industry (FA, QA, R&D, or reliability). Hands-on experience in: Failure analysis / teardown, Root cause investigation. Experience with lithium-ion cell structure and manufacturing is highly preferred.

Knowledge: Strong understanding of: Lithium-ion battery chemistry and structure, Failure mechanisms, Familiarity with FA methodologies: 8D, 5 Why, FTA

Skills: Strong analytical and problem-solving mindset. Data-driven thinking and attention to detail. Good technical reporting and presentation skills. Ability to work cross-functionally in a fast-paced environment

Other abilities: Experience with FA tools (SEM, X-ray, CT, EIS) is a strong advantage. Experience building FA database systems or digital tracking tools is a plus

People also viewed

TTI Network

 

Thanks for joining our Talent Network,

By joining our Talent Network you have not officially applied to a position.

Please apply now to become candidates for vacancies or continue update resume.